CANOGA PERKINS L351 10/100BASE Media Converter User Manual

Page 70

Advertising
background image

EdgeAccess Universal Chassis System

5-4

L351 10/100BASE Media Converter

5.2.2 New Installation

On new installations, make sure that all steps in Chapter 2 are complete:

1. Check that the STA LED is green.

2. Check that the fiber type (multimode or single mode) matches the L351 optical mode.

3. Make these checks:

• All fiber cabling is of the same type; do not mix multimode and single mode cables.
• The fiber optic cable is within the specifications and loss budget of the optic interface

module.

• The line length between the L351 and the remote link does not exceed the allowable loss

budget or receiver saturation.

• All host modules in the link are turned on.
• All fiber cables are connected Tx to Rx and Rx to Tx.

5.2.3 SW2 and SW3 Settings Ignored

If the L351 was installed in a UCS 1000, UCS 1002 or 1020 and set in the User Interface to software
control, it ignores the hardware switch settings. To restore it to hardware control, access the Utilities
screen and reset the configuration to default. For details on setting the L351 hardware switches, see
Chapter 2.

5.2.4 Problems With Fiber Optics

If the System Alarms screen shows that an Extension Port link is down, inspect and clean the cables
and connectors, then replace any damaged fiber. Retest modules after cleaning.