Appendix

FlightDEK-D180 Pilot’s User Guide

11-9

Alert Message

Description

End condition

INTERNAL BATTERY
LOW

You will see this alert only when operating the
unit solely off the internal backup battery. When
its voltage has dropped below a certain threshold,
you will see this alert. Additionally, the voltmeter
will be displayed onscreen. When you see this
alert, it is advisable that you turn the unit off by
pressing the POWER button in Main Menu 1.

The alert will disappear when you press any
button; however, it is advised that you do not
ignore this alert, as it appears when the unit’s
internal battery has very little life left. This alert
will also go away upon the application of either
the external backup battery or Master Power. At
that point, the battery will begin charging off the
external power.

REMOTE COMPASS
NOT DETECTED

The FlightDEK-D180 is unable to communicate
with the EDC-D10A. If you have an OAT
connected to your EDC-D10A, you will lose this
reading, as well.

Ensure that you a) have an EDC-D10A installed
and b) have verified that the wiring to the EDC-
D10A is correct. Please see the FlightDEK-
D180 Installation Guide for more information
on verifying the installation of the EDC-D10A.
This error also can appear if you have updated
the firmware in your FlightDEK-D180 while the
remote compass was not connected. If this is the
case, try uploading the new firmware again with
the EDC-D10A connected. Attempt the
connection within the first few seconds of
operation.
Note that the FlightDEK-D180 does not have
internal magnetic sensors and thus requires the
EDC-D10A be connected.