ChemoMetec NC-3000 User Manual

Page 44

Advertising
background image

991-3003 Rev. 1.0

August 2013

44

2. Gating Setup: Launches the

Gate Configuration

window, where gating settings can be configured

for this plot.

3. New Polygon: Creates a new polygon. Click in the plot area to add points in the polygon. Click in the

gray area around the plot to delete the last point in the polygon. Click on the starting point to close
the polygon.

4. New Quadrant: Creates a new quadrant. Click in the plot area to add the center point of the

quadrant. Optionally click on the quadrant and drag center- and end points. Click away from the
quadrant to unselect and finish quadrant editing.

5. Selected Gate: Edit the selected gate.

Set Alias Name

Show Info

Copy to Clipboard

Delete

6. BMP to Clipboard: Copies the large plot to the clipboard to paste the bitmap image into a preferred

program.

7. Cancel: Closes the large plot without saving the changes to the row.

OK: Closes the large plot and saves the changes to the row.

8. Data source indicator: A small colored square in the upper left corner of the plot area indicates the

source of the cell population (see further details in the section

Row Window

in Plot Manager).

Right-Click Options: Right-click inside the plot area when no gates are selected to get a context menu
offering the following options:

Paste Gate: Paste a polygon- or quadrant gate copied from another scatter plot.

Show Gate Counts: Toggles between displaying counts and percents for the gates.

Delete Image Overlay: Unselects cells added to the

Image Overlay

.

Depending on the state of the large scatter plot, some of the above options may be dimmed or be
replaced with an alternative option, e.g. Show gate counts can toggle with Show gate counts in %.


Right-Click Options: Right-click inside the plot area when a gate is selected to get a context menu offering
the following options:

Copy Selected Gate: Copies the selected gate.

Add Cells Inside Gate to Image Overlay: Selecting this option will add cells inside the selected gate
to the image overlay (only cells that are shown in the plot), causing these cells to be marked with a
non-filled enclosing square.

Add Cells Outside Gate to Image Overlay: Selecting this option will add cells outside the selected
gate to the image overlay (only cells that are shown in the plot), causing these cells to be marked
with a non-filled enclosing square.

Delete Image Overlay: Unselects cells added to the

Image Overlay

.

Advertising