Network video server/ip camera user manual, Com setting – COP-USA WS08 User Manual

Page 34

Advertising
background image

Network Video Server/IP Camera User Manual

34

Set Talkback IP』it is the IP address of client receiving message when talkback request is sent,

this function is an expanded function and not available yet.

Server Name

Name of the server, convenient for memory; e.g. if the server is placed at No.

888 Jiefang Road, then you may name the server as “No. 888 Jiefang Road” for a clear guide of
its location exactly

Reversal Connection of Server』DVS/IP Camera actively connects to the object host on which

the central management software is installed, and the default service port is 6000.

Setting』When the setting corresponding to the button is done, click the button to finish.

4.5.

COM Setting

Profile:

All our DVS/IP Camera products support 12 kinds of common PTZ protocols. If you want to
connect to PTZ equipments, you need to set the parameters of RS485 port under this option, such
as PTZ protocol, address and baud rate.

Steps of setting:

Step I:

First of all, set protocol, address and baud rate of dome or PTZ correctly;

Step II:

The 485 communication cable of dome or PTZ shall be connected with DVS/IP
Camera 485 communication port;

Step III: Select『Channel』(2/4 channels of DVS optional) to set『PTZ Protocol』

In the drop-down menu, select the protocol you need (match with dome or PTZ);
the server supports 12 kinds of common protocols; if there is no any protocol
matching your demands in the drop-down menu, you may upload your own
protocol; the server supports transparent transmission, and default value is Pelco-d.

Step IV: Set『PTZ Address』and『PTZ Baud Rate』

Input the address and baud rate of your PTZ to match with fore-end dome or PTZ.

Step V: Set『PTZ Speed』

Here you set the running speed of dome conveniently and randomly (0~60
optional)