System check, to identify the problem

The system check consists of:

Stator Check

Regulator Rectifier Check

Down stream Check

5.

Stator check: See Figure 7.24.

5a.

Key OFF, unplug the stator from the regulate/
rectifier.

5b.

Check resistance through the stator using a
digital multimeter set to read Ohms.

• It should be between 0.1

Ω and 0.14Ω.

• A high reading indicates a fault in the wind-

ings.

• A low reading indicates a short in the wind-

ings.

• There should be a reading of O.L. (Open

Line) between either lead and the engine
block.

• It is good practice to check the stator cold,

and again when the engine is at operating
temperature.

5c.

Check the raw output of the stator.
See Figure 7.25.

• Connect a meter set to read Volts A.C. to the

output leads of the stator.

• Start the engine and advance the throttle to

3,000 RPM.

• The stator should produce at least 26 Volts

A.C. In some cases, output will be as high as
34 Volts A.C.