Starter Motor

Measure Armature and Commutator Run-Out

Measure the armature core run-out and the
commutator run-out using a dial indicator
(Figure 10-17). Replace the armature if either of
the measurements is not within specifications. See
Starter Motor Specifications on page 10-6 f
or
service limit.

Figure 10-17

Field Coil

Field Coil Continuity Test

Check for continuity between the field coil terminals
using a multimeter (Figure 10-18). The multimeter
should indicate continuity.

If the multimeter does not indicate continuity,
replace the field coil assembly.

Figure 10-18

Field Coil Insulation Test

Check for continuity between either field coil
terminal and the yoke using a multimeter
(Figure 10-19). The multimeter should not indicate
continuity.

If the multimeter indicates continuity, replace the
field coil assembly.

Figure 10-19

Measure Brush Length

Measure the length of the brush (Figure 10-20).
Replace the brush if the length is less than the limit.
See Starter Motor Specifications on page 10-6 for
service limit.

Figure 10-20

0000116

0000119

0000120

0000121

TNV_IDI_ServiceManual_(3TNV72 for YN only).book 14 ページ 2007年11月29日 木曜日 午後2時58分