Mechanical settings (mkii units only), Routing, Mechanical settings (mkii units only) -61 – Elektron Machinedrum User Manual

Page 69: Routing -61

Advertising
background image

GLOBAL SETTINGS

61

1.

Select the CONTROL row in the GLOBAL EDIT menu. Then select PRG CHANGE and
press [ENTER/YES].

2.

You will be presented with available alternatives for handling program changes. If PRG
CHANGE IN
is set to ON the Machinedrum will respond to incoming program changes. If
PRG CHANGE OUT is set to ON the Machinedrum will send program change messages
when a new pattern is selected. If set to OFF no program change messages will be sent.
CHANNEL selects which MIDI channel the program change messages will be received
and sent on. If set to BASE the MIDI channels specified by the BASE CHANNEL will be
used for receiving and sending program change messages. The Machinedrum will
receive program change messages on all four base channels, but only send program
change messages on the first channel in the base channel range. For more info how to
set the base channels, see “BASE CHANNEL” on page 58.

MECHANICAL SETTINGS (MKII UNITS ONLY)

If you have a MKII unit you can select the resolution of the encoders.

1.

Select the CONTROL row in the GLOBAL EDIT menu. Then select MECH SETTINGS
and press [ENTER/YES].

2.

The default resolution setting is 24. Turning an encoder one revolution will cover 24
parameter steps. If you increase the resolution to 32, turning an encoder one revolution
will cover 32 parameter steps.

ROUTING

In the routing menu tracks can be assinged to the six available track outputs. You can also
select how the Machinedrum will react to incoming trig signals.

Advertising