Device tcp connection configuration, Socket port, Configuration properties – Comtrol Modbus TCP User Guide User Manual

Page 42: Edit socket port configuration page

Advertising
background image

42 - Chapter 3. Embedded Configuration Pages

DeviceMaster UP Modbus/TCP User Guide: 2000447 Rev. I

Edit Socket Port Configuration Page

3.5. Edit Socket Port Configuration Page

This section discusses the following:

3.5.1. Device TCP Connection Configuration

3.5.2. Socket Packet ID Settings

on Page 44

3.5.1. Device TCP Connection Configuration

Access to the Edit Socket Port Configuration page is provided by selecting the corresponding socket number
on the Ethernet Device Configuration page (for example, Socket 1).

The remainder of this subsection discusses
the Device TCP Connection Configuration
area on this page.

The other areas of this page are discussed in
the following subsections, which are located
under the 3.6. Common Configuration Areas
(Serial or Ethernet Device)
section:

3.6.1. Serial Modbus Master and
Modbus/TCP Settings

on Page 47

3.6.3. Filtering/Data Extraction
Configuration

on Page 51

3.6.4. Application TCP Connection
Configuration

on Page 54

3.6.5. Saving Port Options

on Page 56

The following table provides information
about configuring the Device TCP Connection Configuration area.

Device TCP Connection Configuration

Ethernet Interface
Name

A user definable string used to describe the serial interface. Valid characters
include a-z, A-Z, 0-9, underscores, spaces and dashes. All other characters will be
discarded. Up to 80 character ASCII string. The default is blank.

Enable

This setting enables/disables the Device Ethernet Device. Enabling this function
allows an Ethernet TCP/IP device to be connected to a PLC and/or application. If
both the PLC and application are connected to the device, both can transmit to and
receive data from the device socket port. However, the PLC and application cannot
communicate directly to each other.

Advertising