Port embedded installation, Building the serial ribbon cable – Comtrol 500 DeviceMaster User Manual

Page 12

Advertising
background image

12 - DeviceMaster 500 User Guide: 2000501 Rev. A

Hardware Installation

Hardware Installation

1-Port Embedded Installation

Installing the DeviceMaster 500 1-Port Embedded system follows these basic
steps:

Building the serial ribbon cable (below).

Mounting the Embedded 1-Port

on Page 13 and installing light pipes.

Attaching the Network and Serial Cables

on Page 14.

Connecting the Power and Verifying Installation

on Page 14.

Observe proper ESD techniques when handling the DeviceMaster 500.

Building the Serial
Ribbon Cable

Use the following information to build a DB9 serial ribbon cable to connect to the
DeviceMaster 500 1-Port Embedded IDC10 connector (J3).

Caution

J3 Header

RS-232

RS-422

RS-485

1

CD

Not used Not used

2

DSR

Not used Not used

3

RxD

RxD-

Not used

4

RTS

TxD+

TRX+

5

TxD

TxD-

TRX-

6

CTS

RxD+

Not used

7

DTR

Not used Not used

8

RI

Not used Not used

9

GND

Not used Not used

10

Not connected

Pin 1

Pin 6

1 2

9 10

Ribbon Cable

10-Pin
Socket

Pin 5

Pin 9

DB9
Male

J3

Advertising