54 - RedBoot Procedures

DeviceMaster 500 User Guide: 2000501 Rev. A

RedBoot Procedures

e.

Click Send.

10. When the RedBoot> prompt appears (after approximately one minute for the

Bootloader and approximately three minutes for SocketServer), type go.

Note: In a few seconds, the ethernet and PWR LEDs cycle through a light

sequence once and then upgrade is complete.

11. If you updated SocketServer: type, fis list and press Enter at the RedBoot>

prompt.

Note: You should see file information for a file called default. If you do not see

this file, repeat the process starting with

Step 6

.

12. Reset the DeviceMaster 500 by typing reset at the RedBoot> prompt.

Note: In a few seconds the ethernet and PWR LEDs cycle through a light

sequence once and the update is complete.

13. Start your internet browser and enter the IP address of the DeviceMaster 500

to verify that the new version of SocketServer loads.

The file name in this screen shows the Bootloader.

RedBoot> go
... Erase from 0x05030000-0x050c0000: .........
... Program from 0x00000000-0x00084801 at 0x05060000: ...
... Erase from 0x050f0000-0x05400000: .
... Program from 0x007a0000-0x007b0000 at 0x053f0000: .

CCCCCCRaw load done: 542721 bytes read
Address range: 00000000-00084800, Entry point: 00000000,
xyzModem - CRC mode, 4241(SOH)/0(STX)/0(CAN) packets, 8 tries

RedBoot> fis list
Name FLASH addr Mem addr Length Entry point
FIS_directory 0x053F0000 0x053F0000 0x00010000 0x00000000
default 0x05030000 0x00000000 0x00090000 0x00000000
RedBoot>

RedBoot> reset
. . .Resetting