Completing the S

ICK LMS Scanner Installation

Use the following procedure to complete a S

ICK LMS Scanner installation.

1.

Connect the LMS Scanner to the DeviceMaster 500 port that you configured
using the RS-422 cable (or optionally the RS-232 cable if you do not want to
use the 500K rate) to the scanner.

Note: Do not connect the power on the LMS scanner at this time.

2.

Open PortVision Plus (Start/Programs/Comtrol/PortVision Plus/PortVision Plus).

3.

Select Scan and
verify that the
DeviceMaster
500 is
connected to
the network
and is running
NS-Link.

4.

Launch
WCOM2 - Test
Terminal
from
PortVision Plus
by selecting
Tools/
Applications/
Test Terminal
(WCom2)
.

5.

Open the
DeviceMaster
500 COM port
that you
configured for the scanner by selecting the appropriate port from the File/Open
menu.

6.

Set the COM port to 9600 baud by using the Settings/Port Settings menu.

Note: The default baud rate for the scanner is 9600. Every time you power

cycle the scanner you must reset this baud rate to communicate with the
scanner.