32 - Device Driver Installation

DeviceMaster 500 User Guide: 2000501 Rev. A

Device Driver Installation

7.

Set WCOM2 to view Hex data by selecting the View/Hex Display menu option.
Hex Display displays a check when selected.

Note: All the communications with the scanner are in Hex format.

8.

Connect the power cord of the scanner to a power source. When the scanner
displays a green light, you should see a message on the WCom2 window.

9.

Use the Port/Send ASCII / HEX String menu to send the appropriate hex
commands using LMS scanner manual to perform these steps:

a.

Send a request to the scanner to start measuring.

b.

Send a request to the scanner to stop measuring.

c.

Send a request to the scanner to set the baud rate to 500K.

d.

After you get the
confirmation, change the
COM port setting in
WCOM2 to 500K by using
the Settings/Port Settings
menu.

e.

Repeat Steps

a

and b to

make sure that the
scanner is working at
500K.

Note: You can use this step for

any baud rate.