Hardware Installation

DeviceMaster 500 User Guide: 2000501 Rev. A - 13

Hardware Installation

Mounting the
Embedded 1-Port

Use the following procedure to mount the DeviceMaster 500 1-Port Embedded
with the 5-30VDC power supply.

Observe proper ESD techniques when handling the DeviceMaster 500.

1.

Carefully remove the DeviceMaster 500 from the anti-static bag, following
standard electrostatic device handling procedures.

Note: Write down the MAC address located on a label on the bottom (solder

side) center of the DeviceMaster 500 because you may need it during
configuration.

2.

Mount the DeviceMaster 500 for your environment using 1/4” stand-offs to
separate the DeviceMaster 500 from the base.

3.

Use one of the following methods to ground the DeviceMaster 500.

Through the power supply by connecting the ground wire on the power
cable using plastic or metal stand-offs.

Through the chassis, using metal stand-offs. If plastic stand-offs are used
to mount the board, then you must ground the DeviceMaster 500 using the
power cable.

Note: The maximum diameter of the metal stand-offs should be 0.175” with a

4-40 machine screw. Metal stand-offs are not provided with the
DeviceMaster 500.

Caution

Non-plated/non-grounded mounting holes 0.116” diameter (+/-0.003”).

WARNING: Holes in hatched area are not mounting holes.

Maximum component height above board is 0.55”.

Ethernet connection J2: J2 overhangs board edge by 0.14” and the height is 0.55”.

LED light pipe mounting holes. The LED light pipes are not provided.

Serial port connector J3: 0.1” pin spacing, 0.025” square pin diameter, and 0.230”
pin height.

Debug port connector J4: 0.1” pin spacing, 0.025” square pin diameter, and 0.230”

Power connector; the mating connector is Weidmuller P/N: 152651.

1

3

4

5

6

7

8

9

Plated/chassis grounded mounting hole 0.116” diameter (+/-0.003”).

2

pin height.

5-30VDC Model