14-17

_________________________________________________________________________________________________________

MAXQ7667 User’s Guide

Figure 14-8 shows single-edge-controlled ADC conversion timing when the ADC is in auto shutdown state. The power-up and acqui-

sition is triggered by the falling edge of the ADC conversion start source signal ADC_CNVST. ADC_CNVST is an internal signal gen-

erated from a combination of all the three conversion start sources previously described.

In single-edged conversions, the ADC control logic provides the necessary power-up, acquisition, and conversion delay.

a) If ADC is in auto shutdown state, it takes a total of 27 ADC clock cycles before the 12-bit result is available.

b) If ADC is not in auto shutdown state, it takes a total of 17 ADC clock cycles before the 12-bit result is available.

Figure 14-9 shows single-edge-controlled ADC conversion when the ADC is not in auto shutdown state.

Table 14-5. ADC Dual- and Single-Edge Modes (continued)

ADC DUAL-

MODE

(SARDUL)

ADC CONVERSION

SOURCE

(SARS[2:0])

ADC CONVERSION

TRIGGER

ADC CONVERSION DESCRIPTION

110

(Continuous)

Write 110 to

SARS[2:0]

Write 110 to SARS[2:0]

• If in auto shutdown, logic requires 8 cycles to power up.

• Sets T/H into track mode.

• ADC control logic provides the required track duration.

• T/H placed in hold after 3 clock cycles.

• Then SAR conversion executes (13 ADC clock cycles).

Conversion continuously repeated every 16 ADC clock cycles.

0

(Single-Edge

Mode)

111

(Start/Busy bit)

Write 1 to SARBY

(Start/Busy Bit)

Write 1 to Start/Busy Bit

• Sets T/H into track mode.

• ADC control logic provides the required track duration composed of power-up

delay (10 cycles), acquisition delay (3 cycles), and settling delay.

• If ADC is in auto shutdown, T/H placed in hold after 11 clock cycles.

• If ADC is not in auto shutdown, T/H placed in hold immediately.

• Then SAR conversion executes (13 ADC clock cycles).

Figure 14-8. Single-Edge ADC Conversion Timing; ADC Previously Off

1

17

27

13

SARBY

ADCDATA

ADCCLK

ADC_CNVST

DATA (n-1)

DATA (n)

ACQUISITION (n)

POWER-UP

CONVERSION (n)