Table 17-5. integer divisor values -19, Maxq7667 user’s guide, Table 17-5. integer divisor values – Maxim Integrated MAXQ7667 User Manual

Page 301

Advertising
background image

Table 17-5. Integer Divisor Values

The burst clock generated can be controlled and manipulated, in a few ways, before it reaches the output pin BURST.

The polarity of the output signal is controlled by the burst polarity bit, BPOL (BTRN.11). Setting it to 0 would keep the signal normally

low with high going pulses. Setting BPOL to 1 keeps the signal high with low going pulses.

The drive strength of the burst signal is controlled by the burst drive strength bit, BDS (BPH.14). This bit selects the drive strength on

the BURST pin. When the BDS bit is set to 0, the output driver is lower (refer to the datasheet for this value); when set to 1, the output

driver is higher (refer to the data sheet for this value).

The burst signal can be stopped from reaching the BURST pin by setting the burst gate bit, BGT (BTRN.8), to 1. Internally the burst

signal is still available for diagnostic purposes. Setting BGT to 0 allows the burst signal to pass through to the output pin.

The BURST output pin can be set to three-state mode by setting the burst three-state bit, BTRI (BTRN.9) to 1. At power-up, BTRI is set

to 1. This places the BURST output pin in a three-state mode, which prevents large amounts of current from flowing through the exter-

nal transformer while the MAXQ7667 is being initialized. During the initialization process BPOL and the other burst parameters should

be set before BTRI is set to 0, which enables the BURST output pin. A pullup or pulldown resistor should be used to hold the external

transistor in the desired state while the MAXQ7667 is being initialized.

17-19

_________________________________________________________________________________________________________

MAXQ7667 User’s Guide

BDIV

BINARY

HEX

Rdivisor

Bdivisor

NOMINAL BURST FREQUENCY IF

f

Clock-Burst-In

= 16MHz

(kHz)

0000

00

12

1333

0001

01

16

1000

0010

02

20

800

0011

03

28

571

0100

04

36

444

0101

05

48

333

0110

06

64

250

0111

07

90

178

1000

08

120

133

1001

(default)

09

(default)

2

160

100

1010

0A

3

240

66.7

1011

0B

4

320

50

1100

0C

5

400

40

1101

0D

6

480

33.3

1110

0E

7

560

28.6

1111

0F

8

640

25

Note: The burst clock-divide select bit selects the divide ratio between the clock source specified by BCKS and the burst and receive path clocks. Note that
the receive path clock is not active for burst-divide ratios of less than 160. Defaults to 1001 upon reset.

Advertising