)U<CR>

Updates the default values of the MPU Data
permanently in the flash.

Examples:

)08$<CR>

Reads data word at MPU address location 0x08
in hex format.

)08$$<CR>

Reads data words at MPU address location
0x08, 0x09 in hex format.

)08$$$<CR>

Reads data words at MPU address location
0x08, 0x09, 0x0A in hex format.

)28:4D$

Read data words in hex.

)08?<CR>

Reads data word at MPU address location 0x08
in decimal format.

)08??<CR>

Reads data words at MPU address location
0x08, 0x09 in decimal format.

)08???<CR>

Reads data words at MPU address location
0x08, 0x09, 0x0A in decimal format.

)28:4D?

Read data words at MPU address location
starting 0x28 to 0x4D in decimal.

)04=12345678<CR>

Writes 0x12345678 to MPU address location
0x04 in the hex format.

)04=12345678=9876ABCD<CR>

Writes 0x12345678 to MPU address location
0x04 and 0x9876ABCD at MPU address location
0x05 in the hex format.

)04=+123<CR>

Writes 123 to MPU address location 0x04 in the
decimal format.

)04=+123=-334<CR>

Writes 123 to MPU address location 0x04 and
-334 to MPU address location 0x05 in the
decimal format.

Advertising