37
CE
Parameter
Location
(hex)
LSB
Default
Comment
Example
CESTATE
0E
5005h
SAG CNT
Bits 15:8 –
determines the
consecutive voltage
samples below
SAG_Threshold
before a sag alarm
is declared. 255 is
the maximum
value.
Current Sensor
Configuration
Bit 7
0 use IA for current
1 use I0 - I1for
current.
Dual Voltage
Bit 6
1-VB is separate
from VA.
0 – Single voltage
input
Reserved
Bit 5
Pulse Selection
(PULSEL)
Bit 4
0 – chooses Outlet
1 (IA input) for
pulse generation
1 – chooses Outlet
2 (IB input) for
pulse generation.
Reserved
Bit 3
Voltage Sensor
Configuration
Bit 2
0 – Isolated mode
uses VA-VB for
Voltage
1 – Non-isolated
mode uses VA for
voltage; V3P3 must
be tied to NTRL; VB
can be tied to
EGND for reversal
detection
Pulse gain factor
Bits 1 and 0
00 – 6x
01 – (6/64)x
10 – 96x
11 – 1.5x
]0E=5001
Selects at least 80 (50h) consecutive
voltage samples below SAG_Threshold
before SAG alarm.
Selects Pulse Gain Factor equal to 6/64
(1h)