Maxim Integrated 6613_OMU_2+2S_URT_V100 User Manual
Page 28
6613_OMU_2+2S_URT_V1_00 Firmware Description Document
UG_6613_060
28
Rev. 1.1
Output
Location
(hex)
LSB
Comment
Example
VAs B Max
79
mW
Maximum apparent power
measured (per second).
If the largest VAs measured
is 300 VARs
)79?<CR>
Returns:
+300.000
Power
Factor B Min
7A
–
Minimum power factor measured.
Minimum is defined as the most
negative or least positive number.
If minimum power factor measured
is –0.6
)7A?<CR> Returns:
-0.600
Power
Factor B
Max
7B
–
Maximum power factor measured.
Maximum is defined as the most
positive or least negative number.
If maximum power factor measured
is 0.9
)7B?<CR> Returns:
+0.900
Phase
Angle B Min
7C
–
Minimum phase angle measured.
If the minimum phase angle
measured is 10 degrees
)7C?<CR>
Returns:
+10.000
Phase
Angle B Max
7D
–
Maximum phase angle measured.
If the maximum phase angle
measured is 70 degrees
)7D?<CR>
Returns:
+70.000
Reserved
7E
–
Reserved
Reserved
Reserved
7F
–
Reserved
Reserved