CE

Parameter

Location

(hex)

LSB

Default

Comment

Example

QUANT IA

16

(IMAX A)

2

*

4.6351E-11

(A

2

)

0

IA input

compensation

added for input

noise and

truncation in the

squaring calculation

for I

2

. Used for

compensation at

low current levels.

Keep below

10000d.

QUANT IB

17

(IMAX B)

2

*

4.6351E-11

(A

2

)

0

IA input

compensation

added for input

noise and

truncation in the

squaring calculation

for I

2

. Used for

compensation at

low current levels.

Keep below

10000d.

Reserved

18

Reserved

Reserved

Gain Adjust

19

16384 is

the default

and is a

gain of 1.

+16384

32767 is max giving

a

gain of 2.

To increase all channels equally by 1%

scale the nominal number, 16384 by

1/(1-0.01). Number to be entered would

be 16549:

]19=+16549<CR>

To decrease all channels 1% scale the

nominal number, 16384 by 1/(1+0.01).

Number to be entered would be 16222:

]19=+16222<CR>

Reserved

1A-1B

Reserved

Reserved