Maxim Integrated 6613_OMU_2+2S_URT_V100 User Manual

Page 23

Advertising
background image

UG_6613_ 060

6613_OMU_2+2S_URT_V1_00 Firmware Description Document

Rev. 1.1

23

Output

Location

(hex)

LSB

Comment

Example

Reserved

2F

Reserved

Reserved

Vrms A Min

30

mV

Minimum Vrms measured

If the minimum line voltage

measured was 105 V

)30<CR>

Returns:

+105.000

Vrms A Max

31

mV

Maximum Vrms measured

If the maximum line voltage

measured was 130 V

)31<CR>

Returns:

+130.000

Watts A Min

32

mW

Minimum active power measured

(per second)

If the minimum power measured

is 80 Watts

)32?<CR>

Returns:

+80.000

Watts A Max

33

mW

Maximum active power measured

(per second)

If the maximum power measured

is 200 Watts

)33?<CR>

Returns:

+200.000

Irms A Min

34

mArms

Minimum rms current measured.

If the smallest current measured is

1 Amp

)34?<CR>

Returns:

+1.000

Irms A Max

35

mArms

Maximum rms current measured.

If the largest current measured is

30 Amps

)35?<CR>

Returns:

+30.000

VARs A Min

36

mW

Minimum reactive power measured

(per second).

If the largest VARs measured

is 80 VARs

)36?<CR>

Returns:

+80.000

VARs A Max

37

mW

Maximum reactive power

measured (per second).

If the largest VARs measured

is 300 VARs

)37?<CR>

Returns:

+300.000

VAs A Min

38

mW

Minimum apparent power

measured (per second).

If the smallest VAs measured

is 80 VARs

)38?<CR>

Returns:

+80.000

Advertising