3.1.5. Main Lift Reaction:
The main lift reaction time affects how long the main lift waits between adjustments. The main lift
reaction time can be adjusted from 0 to 3. A setting of 1 is slow and a setting of 3 is the fastest reaction

time. A reaction time of 0 turns the main lift control off. A slower main lift reaction time can be

beneficial in uneven crops to prevent the boom from making unnecessary movements. A reaction time of

zero can be beneficial in tall crops where the crop is being pushed over by the sprayer chassis to prevent
the center section from moving too low.

3.1.6. Learned/Expected Crop Height:
The Learned Crop Height setting is used when spraying in Hybrid Mode™. When Learned Crop Height
is checked, the UC5™ system will attempt to learn the average crop height using all crop readings that

are measured by the ultrasonic sensors.