When the Headland Assist feature is enabled, a trigger type must be selected to activate it in the field.

The trigger should be set to the Main Lift Up/Down switch.

NOTE: The Remote Auto input line will not work on Rogator Sprayers Main Lift Switch.

If the Main Lift switch is enabled as the trigger, the Headland Assist will be triggered when the operator

presses the “main up” switch while in Automatic Mode. By pressing the “main down” switch the boom

will return to Automatic Mode. When in Manual Mode the Main Lift switch will operate the normal main
lift function.

3.7.3. Oil Temp Alarm:
The Oil Temperature Alarm is normally defaulted to on. When this option is enabled (checked), an error
message will appear if the NORAC valve block reaches a temperature of 95°C (203 °F). It will appear

once and will not repeat until power has been cycled.