Short circuit test – NORAC UC5-BC-AGCO-RMC User Manual

Page 34

Advertising
background image

34 |

5.3.4. Short Circuit Test
1. Disconnect all the height sensors, modules, roll sensors and power from the NORAC CANbus.

Ensure all cables and terminators are connected together.

2. Using an ohm meter, test the resistance of all the pin combinations on the 6-pin connector (C01).
3. If an incorrect value is measured, continue by testing at the next connection until the problem cable is

isolated.

Pin #

Pin #

Value

1 2

Open Circuit

1 3

Open Circuit

1 4

Open Circuit

1 5

Open Circuit

1 6

Open Circuit

2 3

Open Circuit

2 4

Open Circuit

2 5

Open Circuit

2 6

Open Circuit

3 4

75Ω ± 10Ω

3 5

Open Circuit

3 6

Open Circuit

4 5

Open Circuit

4 6

Open Circuit

5 6

Open Circuit

Advertising