5.7. Replacing Components

5.7.1. Replacing a height or roll sensor, input or valve module:

 Performing a Retune or Automatic Setup is NOT necessary.
 Turn off the power, replace the component and turn on the power. The system will recognize

that there is a new component.

5.7.2. Replacing a control module:

 Performing a new Automatic Setup is required.

5.7.3. Swapping height or roll sensor locations:

 The sensors need to be reconfigured (mapped) to the new locations.