Height sensor test – NORAC UC5-BC-AGCO-RMC User Manual

Page 29

Advertising
background image

29 |

5.2. Height Sensor Test

1. Inspect foam pads and sensors. Install clean dry foam pads if necessary.

2. Perform this test over level bare soil or gravel. The system must be in Manual and Soil mode.

3. Level the booms and adjust the main lift to the bottom of the stroke.

4. Navigate to the height readings screen (Run Screen -> Settings -> Next -> Next -> Diagnostics ->

Sensors).

5. Check the readings of all the Height Sensors while raising the center section.

6. A continuous and accurate height reading from 10 inches (25 cm) to 80 inches (200 cm) should be

seen.

7. Repeat steps 2 to 6 in Crop Mode.

Serial Number

Advertising