E-57

Connecting Multiple Bridge Satellite Cradles (HA-A61IO)

Use the modular cable for the connections.
You can daisy chain multiple Bridge
Satellite Cradles by connecting the C-OUT
port of the first unit that is the nearest to the
host computer to the C-IN port of the next
unit that is sitting to the first unit with DT-
888RSC cable (RS-422 Modular cable) as
shown in the figure below.

Important!

You can use optional RS-422 Modular Cables (DT-888RSC) to link up to eight
Bridge Satellite Cradles.

To host computer

Daisy chain connection
cables (DT-888RSC)

RS-232C
cable or
USB cable