14

PRG SERIES 400

®

POWER AND DATA DISTRIBUTION SYSTEM USER MANUAL

Figure 1-9: Rack Components / Rear View

120 x 6

TRUNK A

MODEL 20-9680-1915

120V

TRUNK B

120 x 6

120 x 6

TRUNK A

MODEL 20-9680-1915

120V

TRUNK B

120 x 6

120 x 6

TRUNK A

MODEL 20-9680-1915

120V

TRUNK B

120 x 6

120 x 6

TRUNK A

MODEL 20-9680-1915

120V

TRUNK B

120 x 6

120 x 6

TRUNK A

MODEL 20-9680-1915

120V

TRUNK B

120 x 6

120 x 6

TRUNK A

MODEL 20-9680-1915

120V

TRUNK B

120 x 6

MAIN BREAKER MUST BE SIZED

NEUT

INPUT CONECTIONS

GND

NEUT

400A PER Ø

MAXIMUM

208V / 15A

120V / 15A

208V / 15A

3Ø USA & CANADA

GND

120V / 208V

50-60 Hz

BUS POWER

NEUT

RACK LIGHTS

FOR BRANCH CIRCUIT USE ONLY

OFF

SYSTEM

POWER / DATA
DISTRIBUTION

MODEL 23-9680-0650

S-400

MASTER

ON

PUSH

TEST

TO

POWER

FRONT REAR

MUST BE MADE

TO PROTECT CABLES FEEDING THIS RACK

GND

ORDER:

1) CONNECT GROUND
2) CONNECT NEUTRAL
3) CONNECT PHASES

IN THE FOLLOWING

DISCONNECT IN
REVERSE ORDER

Breaker Module (rear view) - provides Trunk Outputs A
and B for distribution of power and data to Breakout Boxes.

Input Power Connectors - 400 Amp Cam-Lok style
connectors for input of house power service.

Convenience Outlet (2) - Edison style receptacle, which
provides power for optional work lights, test equipment, etc.

Neutrik® Power Outlet (2 pair) - provides power for
control consoles and/or auxiliary signal processors.

Rear Rack Light - provides illumination
for rear side of rolling rack.

Rack Light On/Off Switches - on/off switches
for front and rear rack lights.

Pilot Light - indicates when power is applied to rack
system. Provides a Push-To-Test function.

Master On Switch - powers up entire rack system.

Master Off Switch - safely powers down entire rack system.

15A Circuit Breakers - protects convenience
outlets, Neutrik connectors and L6-20 connector.

L6-20 Power Outlet - provides 208V power for a single
fixture such as a VARI

❋LITE® VL3000™ Spot Luminaire.

Test Points - color coded test point
jacks used to check rack voltages.

Phase Indicators - neon indicators light when
power is applied to rack input connectors.

Output Power Connectors - 400 Amp Cam-Lok style
connectors used for tapping power to another rack.

EXAMPLE CONFIGURATION

S400 Rack Components May Vary

Advertising