Front of House Breakout Module

The Front of House (FOH) Breakout Module provides a convenient method for connecting consoles and accessories
at the mix riser position. It provides power outlets for up to 12 devices, each of which are protected by an individual
circuit breaker. Using the FOH Breakout Module, both a primary and backup console can be connected to the system.
The module provides 10 standard DMX512 inputs for inputting console data into the Ethernet stream and two
Ethernet inputs for any Ethernet signal such as Art-Net or HOG® Ethernet. DMX512 universes can be selected and
controlled using the built-in Menu Display.

The following illustration provides a detailed description of the Front of House (FOH) Breakout Module connections,
controls and indicators.

Figure 1-13: Front of House Breakout Module Connections, Controls and Indicators

10

11

RESET

PORT 1

PORT 2

ETHERNET

Z-N

X-N

Y-N

DMX

TRUNK

DATA

LINK

Rx

Tx

Z-X

Y-Z

X-Y

FRONT of HOUSE MODULE

MODEL 20-9680-8615

6

AC LINE VOLTS

208V/15A

XØ-N

YØ-N

ZØ-N

XØ-YØ

YØ-ZØ

120V/15A

1

FOR BRANCH CIRCUIT USE ONLY

2

3

4

5

DMX INPUTS

ZØ-XØ

3

7

DMX Rx

RDM Rx

RDM Tx

RDM Tx

8

4

RESET

1

RDM Rx

DMX Rx

DMX Rx

RDM Tx

RDM Rx

2

DMX

9

5

Menu Display - used to configure, test, and access
internal status information for the Series 400 Rack
system using associated soft-programmable buttons.

120V/15A Circuit Breaker Switch (3) -
provides protection for associated 120V
connectors.

Ethernet Connectors (Ports 1 & 2) - allows
Ethernet connection to system. Accepts
standard Ethernet or Neutrik® EtherCon®
connectors.

NOTE: These Ethernet Ports are source-
assignable Art-Net input ports, which are
mutually exclusive with the top two DMX input
ports. Refer to

"Configure Inputs – Front

of House"

on page 41

for more information.

DMX Input Connectors (10) - DMX512 in
from console or controller.

DMX LEDs - indicates valid
DMX512 receive, RDM receive
and transmit when lit.

Ethernet LEDs - indicates valid Ethernet
link, transmit and receive when lit.

Trunk Data LEDs (A & B) -
indicates valid Trunk cable
data link and data flow.

208V/15A Circuit Breaker Switch (3) -
provides protection for associated
208V Neutrik connectors.

Trunk Connector -
provides trunk cable
connection (from Breaker
Module or Trunk DC Adapter).

Convenience Outlets -
Edison style receptacles.

Neutrik® Power Outlets -
provides power for control
consoles and/or auxiliary
signal processors.

Power Selector -
selects phase
power output.

SIDE VIEW

A/B Switch Input - 7-pin
XLR connector for input
of optional A/B Switch.

Intercom Input - 3-pin
XLR connector for input
of intercom system.