PRG SERIES 400

®

POWER AND DATA DISTRIBUTION SYSTEM USER MANUAL

29

Installing an Ethernet Switch

A Series 400 Ethernet Switch can be used independently or installed directly in a Series 400 rack chassis, using any
blank space above the LED Meter Module.

To install in Series 400 rack:

Step

1. Install Ethernet Switch as required in top portion of rack chassis (Figure 2-6).

Step

2. At Ethernet Switch rear panel, connect AC Line Cord 208V PowerCon® Cable (supplied) to Neutrik®

connector.

Step

3. After power is applied, verify that ON indicator is lit.

Step

4. At front panel, connect data cables as required.

Figure 2-6: Additional Rack Space

The Series 400 10-Port Ethernet Switch connects Ethernet devices using

both

CAT5e copper wire

and

armored fiber

optic cable. Copper wire communication ports conform to 10/100Base-Tx standards and the fiber ports conform to
10/100Base-Fx standards. The Series 400 7-Port Ethernet Switch connects Ethernet devices using

only

CAT5e

copper wire.

Figure 2-7: Ethernet Switch Connection Options

3U of rack space for
adding additional signal
processing devices.

EXAMPLE CONFIGURATION

S400 Rack Components May Vary

LED Meter Module

AC Input

Fiber Optic Out to Additional Switches

1

0

/1

00B

ase-T

1

0

/1

00B

ase-T

1

0

/1

00B

ase-T

1

0

/1

00B

ase-T

1

0

/1

00B

ase-T

1

0

/1

00B

ase-T

1

0

/1

00B

ase-T

F

iber Op

tic

F

iber Op

tic

Virtuoso Nodes

or

Any Ethernet Device

(up to 7)

SERIES 400 ETHERNET SWITCH

Input from

a Virtuoso Console

or another switch

Input from

a Virtuoso Console

or another switch

10-Port Model Only

Advertising