POWER AND DATA DISTRIBUTION SYSTEM USER MANUAL

45

Setup 1 and 2

These menus allow configuration of system options and reset to defaults.

The highlighted option can be changed by selecting the down arrow (

) or up arrow (

). Move to the next universe by

selecting

next

. Pressing

done

will save changes and return to the main menu.

Name

+

Displays the current module device name.

+

To edit the device name, first select one of the arrow buttons, (

) or (

), while the Name menu entry is selected.

This selection will open the module name characters as fields and allow for editing. Press

next

to move to the

character(s) to be modified. The allowed characters are: letters 'a' - 'z', numerals '0' - '9', and the blank or space
character ' '. The arrow buttons will scroll through the allowed characters in the order: letters, blank, numerals
(assuming that the Up button is pressed and the initial value is the letter 'a'). If the first character of the name is a
letter, it is uppercase. All other letters are lowercase.

+

Once name editing is initiated, pressing

next

will cycle through all of the available name character positions,

followed by moving to the

Display

field, which closes name editing. The other menu entries follow as normal,

before returning to the name field. Upon returning to the name field, it will be necessary to again initiate name
editing if further modification is required. Until name editing is initiated, pressing

next

will simply cycle through the

menu items in order, starting with the name entry.

Display

+

Sets DMX512 universe display to either alpha (A-JV) or numeric (000-255).

Merge

+

Enables the ability to have more than one DMX universe input specified for the same universe. Options include 2-
Way, 3-Way and 4-Way which allows up to four inputs per universe. Merging operates under the Highest Takes
Precedence (HTP) rule and is a system-wide option. Once enabled, all inputs have merge capability.

Reset

+

The

Reset

option allows reset of all the input and outputs to the default settings. To reset to defaults, select

default

in this field and then press

done

while the reset option is still selected.

Light

+

The

Light

option (page 2) allows the display backlight to be turned on or off. This is accomplished by pressing

either arrow button (

) or (

) when the

On/Off

indication is selected. The backlight will go off (entering the

off

mode) and the indicator will be changed to

Off

. To return to the

on

mode, press either arrow button when the

Off

indication is selected. The backlight will be turned on and the indication will change to

On

.

+

If the backlight is in the

off

mode, pressing a button will turn on the light for 10 seconds, at which time it will

automatically turn itself off. Note that pressing a button while the light is temporarily on, will reset the timer. If the
light is in the

on

mode, it will stay on permanently unless it is manually turned off as described above.

+

When the backlight is in the

off

mode, the light will be turned on for about ten (10) seconds every time a button is

pressed or the module is reset. The mode is saved whenever

done

is pressed. In order to change the mode, go

to the SETUP 2 screen and explicitly change the mode by pressing an arrow button (

) or (

) and exiting by

pressing the

done

button.