SYSTEM INPUTS

SWITCH

10 – 30V
Standard Run Mode
Preheat Run Mode
Supplemental Run Mode

COOLANT PUMP

10 – 30V

AUXILIARY

Allows independent operation of Coolant Pump through
the Proheat Control Module

POWER

12 Volt or 24 Volt

M50 12V

M50 24V

M80 12V

M80 24V

RATING BTU/hr (kW)

50,000 (15)

50,000 (15)

80,000 (23)

80,000 (23)

SYSTEM VOLTAGE

Nominal DC Voltage (Range)

12 (10 – 15)

24 (20 – 30)

12 (10 – 15)

24 (20 – 30)

CURRENT DRAW (MAX) Amps

9.5

5.2

8.5

5.2

FUEL CONSUMPTION US gal/hr (L/hr)

0.48 (1.8)

0.48 (1.8)

0.78 (2.95)

0.78 (2.95)

IGNITION TYPE

Electronic Spark Ignition

COOLANT OUTPUT TEMPERATURE MAX.

185°F (85°C)

AMBIENT OPERATING TEMPERATURE

-40°F to +122°F (-40°C to +50°C)

WEIGHT lbs (kg)

53 (24)

HEAT EXCHANGER CAPACITY US gal (l)

0.5 (2)

COOLANT SYSTEM

Minimum Capacity US gal (l)

2.64 (10)

2.64 (10)

2.64 (10)

2.64 (10)

Recommended Flow Rate Through

Heater US gpm (lpm)

5 (19)

5 (19)

7 (26.5)

7 (26.5)

PROHEAT G-I PCM SERVICE MANUAL

1-1

TECHNICAL
SPECIFICATIONS

1.0

SYSTEM OUTPUTS

AUXILIARY OUTPUT

Same as System Voltage
Maximum 1 Amp draw (over-load shut-off protection)
High-side switched

SWITCH/TIMER

Same as System Voltage

POWER

Maximum 1 Amp draw (over-load shut-off protection)
High-side switched

COOLANT PUMP

Same as System Voltage
Maximum 10 Amp draw (over-load shut-off protection)
High-side switched

INDICATOR LIGHT

Same as System Voltage
Maximum 1 Amp draw (over-load shut-off protection)
High-side switched

DANGER

Do not use gasoline.

FUEL TYPES

COMPATIBLE

Diesel (ULSD, #1, #2, Arctic), JP8, Jet A1

Bio Fuels - Contact Proheat www.proheat.com