Annual maintenance 5.2, Warning – Proheat M80 User Manual

Page 75

Advertising
background image

PROHEAT G-I PCM SERVICE MANUAL

5-2

1.

Clean Heater Enclosure

Clean any accumulated debris or dust from the components.

Make sure the opening around the exhaust pipe is clear.

Visually inspect all the components for wear or damage.

Ensure that the burner air intake is clear.

Do not pressure wash.

2.

Check Exhaust System

Check the exhaust system carefully. Clean as necessary.

Make sure the exhaust pipe is vented safely away from the vehicle.

Check the pipe for dents, restrictions or severely corroded areas.

Replace the exhaust pipe and clamps if necessary.

Ensure the exhaust pipe clamp is tight and the exhaust pipe

is secure.

3.

Check Heat Exchanger

Remove the burner head assembly and combustion tube to access

the inside of the heat exchanger.

To maintain optimum heat output, clean any combustion deposits

that may have accumulated on the heat exchanger fins.

Use a wire brush to loosen the deposits and a vacuum to suck

them out.

Ensure exhaust pipe is clean and free from restriction.

4.

Check Cooling System

Check all heater hoses and connections for signs of leakage

or damage.

Repair or replace as required.

5.

Check Power Source

Check the condition of the power source and connections.

The heater will not function properly with a faulty power source or

corroded connections.

6.

Check Fuel System

Check the fuel system for damaged fuel lines or leakage.

Make sure the clamps on the fuel lines are secure.

ANNUAL MAINTENANCE

5.2

ORIENTATION
BOSS

HEAT EXCHANGER

FLANGE NOTCH

Figure 5-2: Heat Exchanger

WARNING

Shock hazard due to voltage.

Advertising