Temperature sensor t2 diagnostic code 7 and/or 9, Ignition module diagnostic code 10, Notice – Proheat M80 User Manual

Page 66

Advertising
background image

PROHEAT G-I PCM SERVICE MANUAL

4-35

TEMPERATURE SENSOR T2 Diagnostic Code 7 and/or 9

Go to Temperature Sensor T1 Diagnostic Code, page 4-31.

IGNITION MODULE Diagnostic Code 10

Indicates an over-load fault is detected.

Troubleshoot the Ignition Module diagnostic code based on:

Ignition Module and G-I PCM – electrical.

Test procedure – Ignition Module and G-I PCM:

a)

Disconnect all harnesses at the G-I PCM.

b)

Disconnect the fuel supply line.

c)

Loosen and back out the burner head mounting (2) bolts five to six turns

allowing enough room to rotate the burner head 15° counter-clockwise

and remove.

d)

Disconnect the Ignition Module connector at the G-I PCM.

e)

Reconnect the power and switch harnesses at the G-I PCM.

f)

Switch the PROHEAT on and operate for at least one complete cycle.

Observe the operation.

If an Ignition Module diagnostic code is NOT indicated and the PROHEAT

attempts to operate, the Ignition Module is faulty. Go to Ignition Module

replacement, page 4-21.

If the Ignition diagnostic code is indicated, the G-I PCM is faulty. Go to G-I

PCM replacement, page 4-41.

4.1.11

(10 Flashes)

4.1.10

(7 or 9 Flashes)

Figure 4-41: Burner Head Removal

MOUNTING EARS (2)

MOUNTING BOLTS (2)
TORQUE = SEE SECTION 1.3

COOLANT PUMP

SWITCH INPUT

TEMP SENSOR 1

POWER

FUEL INLET

NOTICE

All plugs/harnesses must be rein-

stalled into the Proheat Control

Module (G-I PCM) before heater goes

back into service.

Advertising