4-30

Procedure – Low voltage testing:

a)

Inspect the wiring harnesses and connections for corrosion and proper

fit. Clean if necessary.

b)

Using a multimeter set for voltage, measure across the positive and

negative battery terminals or at the supply source.

If the voltage is below the required voltage, service the batteries and/or

charging system as per OEM supplier recommendations.

If the voltage level is within the operating range, go to item 'c'.

c)

Locate and measure across pins D and B in the G-I PCM Data Link

connection. Perform this with the PROHEAT off and then switched on.

If the voltage is within the operating range and a Voltage diagnostic code

is indicated, the G-I PCM is faulty. Go to G-I PCM replacement, page 4-41

If the voltage falls below the required voltage when the Motor starts,

check the wiring from the supply source to the PROHEAT G-I PCM.

Figure 4-36: G-I PCM Datalink Connection

G-I PCM DATALINK
CONNECTION

F

D

E

A

C

B

RED (+)

Figure 4-35: Voltage Measurement

TO PROHEAT

BLACK (-)

Advertising