PROHEAT G-I PCM SERVICE MANUAL

4-24

Motor or G-I PCM – Check:

a)

Electrical function – Open circuit motor.

b)

Electrical function – Open circuit G-I PCM.

Test Procedure – Open circuit Motor:

a)

Disconnect the Motor connector at the G-I PCM.

b)

Using a multimeter set for resistance (Ohms) measure across pins A and B.

c)

Check for an open circuit.

If an open circuit is detected, go to Motor replacement, page 4-25.

If an open circuit is not detected, go to Test Procedure – Open circuit G-I PCM.

Test Procedure – Open circuit G-I PCM:

a)

Disconnect the Motor connector and Temperature Sensor 1 at the G-I PCM.

b)

Reconnect the power and switch harnesses at the G-I PCM.

c)

Switch the PROHEAT on and measure voltage across pins A and B of the G-

I PCM Motor connection.

If the correct nominal system voltage (12 or 24) is measured, the G-I PCM

is OK. Go to Test Procedure – Open circuit Motor.

If no voltage is measured, the G-I PCM is faulty. Go to G-I PCM replacement,

page 4-41.

Figure 4-30: Motor Electrical Resistance Measurement

MOTOR

Figure 4-32: G-I PCM Motor Output Voltage Measurement

LOCK

Figure 4-31: Connector Removal

LOCK

Figure 4-29: Connector Removal

G-I PCM MOTOR CONNECTION

MOTOR

START: Motor and/or

G-I PCM fault

(1 Flash)

CAUTION

DO NOT connect Motor directly to

batteries or another power source

as it will damage the Motor.

NOTICE

All plugs/harnesses must be rein-

stalled into the Proheat Control

Module (G-I PCM) before heater goes

back into service.