Physical 1.1 – Proheat M80 User Manual

Page 15

Advertising
background image

PROHEAT G-I PCM SERVICE MANUAL

1-2

EXHAUST
(SEE NOTE 2 AND 4)

-4 JIC MALE FUEL INLET (INTERNAL
FUEL FILTER) (SEE NOTE 5)

2.75 (70)

12.60 (320)

23.24 (590)

4.45

(113)

8.14 (207)

2.03 (52)

FRONT VIEW

6 x .41 (10)

BOTTOM VIEW

AIR INTAKE
ALTERNATE
SNORKELS
AVAILABLE
(SEE PAGE 1-3 )

3.23

(82)

3.98

(101)

SIDE VIEW

SERVICE SPACE REQUIREMENT
(MAY VARY SEE NOTE 3 & PAGE 1-3)

G-I PCM

5.39

(137)

8.58

(218)

7.63

(194)

REAR VIEW

4.33

(110)

5.90

(150)

4 x M8 x 1.25 MOUNTING PEM NUTS

HEAT EXCHANGER
(SEE NOTE 6)

.75 (19)

10.13 (257)

9.00 (229)

5.77

(147)

T1 PRIMARY TEMPERATURE
SENSOR SEE NOTE 8

9.55 (243)

TOP VIEW

T2 SECONDARY TEMPERATURE
SENSOR LOCATION (SENSOR
NOT SHOWN) SEE NOTE 8

INLET SEE NOTE 8

OUTLET SEE NOTE 8

2 x 1.50 (38)

1.97 (50)

1. DIMENSIONS ARE IN INCHES (MILLIMETERS IN BRACKETS).

2. TYPICAL EXHAUST CUTOUT 3.25" CENTERED ON EXHAUST.

3. SERVICE SPACE REQUIRED TO REMOVE BURNER HEAD AND

COMBUSTION TUBE FOR PERIODIC INSPECTION AND CLEANING.

4. THE EXHAUST PIPE SHOULD HAVE A MINIMUM DIAMETER OF

2.75", A MAXIMUM LENGTH OF 5' AND HAVE NO MORE THAN
180° OF BENDS.

5. ALTERNATE FUEL INLET CONFIGURATIONS AVAILABLE, SEE

PARTS BOOK FOR FURTHER INFORMATION.

6. ALTERNATE HEAT EXCHANGERS AVAILABLE, SEE PARTS BOOK

FOR FURTHER INFORMATION.

7. SNORKEL HOSE REQUIRED FOR THIS AIR INTAKE OPTION.

CONTACT TECH SUPPORT AT WWW.PROHEAT.COM FOR
LENGTH AND BEND RESTRICTIONS

8. THE INLET AND OUTLET CAN BE REVERSED WITH THE ADDITION

OF A T2 SECONDARY TEMPERATURE SENSOR.

NOTES:

PHYSICAL

1.1

Advertising