PROHEAT G-I PCM SERVICE MANUAL

2-2

Coolant is circulated through the heat exchanger via the inlet and outlet

ports. Heat is transferred from the heat exchanger through the inner wall of

the exchanger into the coolant. The exhaust gases are directed out through

the exhaust port.

Measures the coolant temperature near the outlet port of the heat exchanger

and sends this information to the G-I PCM. This sensor also measures the

inner heat exchanger surface temperature for an overheat condition. It must

be connected at all times for overheat protection.

For installations where the coolant flow through the heat exchanger is

opposite of what is specified on page 1-2 and page 2-3.

Circulates coolant through the PROHEAT and vehicle heating system.

Depending on the PROHEAT installation, it may be operated by the G-I PCM.

Heat Exchanger:

Coolant Pump:

Temperature Sensor 1:

Temperature Sensor 2: