PROHEAT G-I PCM SERVICE MANUAL

4-33

Temperature Sensor replacement:

a)

Isolate the coolant system at the PROHEAT inlet and outlet ports for

minimal coolant loss using valves in the system or hose clamps.

b)

Remove main sensor mount using a 1" wrench and/or secondary sensor

using a 13 mm wrench.

c)

Reinstall the new sensor. Ensure that the O-ring and O-ring seat are

clean. Install the sensor until it bottoms out on the mounting boss.

WARNING

NEVER remove coolant lines when

the engine is hot – escaping steam

or scalding water could cause

serious personal injury. Loosen the

coolant line clamps slowly,

allowing the pressure to escape

before removing completely.

Figure 4-39: Temperature Sensors

T1

T2

TEMP SENSOR T1: Step 2

(7 or 9 Flashes)

MAIN SENSOR
TORQUE = SEE
SECTION 1.3

SECONDARY SENSOR
(IF EQUIPED) TORQUE TO
50 in-lbs ±5 in-lbs
(5.6 Nm ±0.5 Nm)

Temperature Sensor and G-I PCM electrical (dual sensors) – Check:

a)

Temperature Sensor and G-I PCM electrical function.

Test Procedure – Sensor and G-I PCM:

a)

Remove Temperature Sensor connector from G-I PCM connection T1.

b)

Remove Temperature Sensor connector from G-I PCM connection T2.

c)

Swap the connectors. T1 to T2 and T2 to T1.

d)

Switch the PROHEAT on:

If a Temperature Sensor T1 diagnostic code is now indicated, the sensor

is faulty. Go to Temperature Sensor replacement.

If a Temperature Sensor T2 diagnostic code is still indicated, the G-I PCM

is faulty. Go to G-I PCM replacement, page 4-41.

NOTICE

All plugs/harnesses must be rein-

stalled into the Proheat Control

Module (G-I PCM) before heater goes

back into service.

NOTICE

All plugs/harnesses must be rein-

stalled into the Proheat Control

Module (G-I PCM) before heater goes

back into service.