Proheat M80 User Manual

Page 71

Advertising
background image

PROHEAT G-I PCM SERVICE MANUAL

4-40

c)

Disconnect the Datalink harness at the G-I PCM. Using a multimeter set

for voltage, measure across pins D and B in the PCM Datalink connection.

If voltage is read and it is of the correct value, the fuse is OK.

If voltage is not present, check the G-I PCM fuse.

Procedure – G-I PCM fuse replacement:

a)

Disconnect all harnesses at the G-I PCM.

b)

Disconnect the fuel supply line.

c)

Loosen and back out the burner head mounting (2) bolts five to six turns

allowing enough room to rotate the burner head 15° counter-clockwise

and remove.

d)

Remove blower housing (2) screws and blower housing.

MOUNTING BOLTS (2) TORQUE = SEE SECTION 1.3

COOLANT PUMP

SWITCH INPUT

TEMP SENSOR 1

POWER

FUEL INLET

Figure 4-47: Burner Head Removal and Motor Mechanical Check

Figure 4-46: G-I PCM Datalink Connection

G-I PCM DATALINK
CONNECTION

F

D

E

A

C

B

RED (+)

BLACK (-)

FUSE COVER AND FUSE

Advertising