PROHEAT G-I PCM SERVICE MANUAL

4-41

e)

Remove the fuse cover and using needle nose pliers or a fuse removal

tool remove the fuse.

If the fuse is blown, replace the fuse and check the PROHEAT current

draw. Go to page 4-29.

If the fuse is OK, the G-I PCM is faulty. Go to G-I PCM replacement below.

G-I PCM replacement:

a)

Disconnect the Fuel Shut-off Valve and Ignition Module connectors at

the G-I PCM.

b)

Remove the blower housing (2) screws and blower housing.

c)

Remove the blower retaining snap ring and slide the blower off the

Motor shaft.

d)

Remove the Air Compressor filter.

e)

Disconnect the Motor connector at the G-I PCM. Remove the G-I PCM.

f)

Reinstall the new PCM following items 'e' back to 'a'.

g)

Reconnect the burner head by mounting it against the heat exchanger

face, turning it clockwise to engage the mounting ears on the bolts.

h)

Reconnect electrical harnesses and fuel supply line.

i)

Switch the PROHEAT on and operate for at least one complete cycle.

Observe the operation.

Figure 4-49: G-I PCM Replacement

BLOWER

BLOWER RETAINING SNAP RING

AIR COMPRESSOR FILTER

G-I PCM

SCREWS (2)
TORQUE = SEE
SECTION 1.3

G-I PCM MOTOR CONNECTION

LOCK

Figure 4-48: Connector Removal

NOTICE

All plugs/harnesses must be rein-

stalled into the Proheat Control

Module (G-I PCM) before heater goes

back into service.