Failure indication – Toa FS-7000 SERIES Manual User Manual

Page 30

Advertising
background image

30

9. FAILURE INDICATION

The FS-7000CP, FS-7000JP, FS-7000RF, FS-7000RM, FS-7006PA, and FS-7012PA are equipped with
failure indicators that show the status of any problems that may occur. When such an indicator lights or
flashes, it means that a problem may have occurred in the equipment or in the wiring.
If the power indicator is not illuminated, the equipment could be malfunctioning. In such cases, check to see if
power is being supplied correctly, or if a fuse has blown. A blown fuse often means that the problem may have
occurred within the wiring as well as in the equipment itself.
In such cases, replace the fuse(s) and check the correctness of the wiring before turning the power on again.

If an indicator lights continuously or flashes, the following possible causes may be considered:

Symptom

Possible Cause

Check/Remedy

One or more of the speaker lines have
shorted, causing the associated line
protection fuse of FS-7000JP to blow.

FS-7000CP's
Speaker Line Short
indicator lights.

FS-7000JP's
Speaker Line
Indicator lights red.

The speaker line corresponding to the FS-
7000JP's Speaker Line indicator that
continuously lights red may be shorted.
Locate and fix the speaker line short,
replace the line protection fuse, then press
the Reset switch mounted on the rear
panel of the FS-7000JP.

Communications are not being
performed correctly with the FS-
7000RM units of the number
designated using the setting switch, or
equipment failures may have occurred.

Communication with the FS-7000RF is
not being performed correctly, or
equipment failures may have occurred.

FS-7000RF's Fault
indicator lights red.

FS-7000RF's Fault
indicator flashes
red.

FS-7000RM's Fault
indicator lights.

• Confirm that the number that has been

set using the setting switch agree with
the actual number of the connected FS-
7000RM units.

• Confirm that the FS-7000RM's address is

set correctly.

• Confirm that there is no fault with the

wiring leading to the FS-7000RM.

If all of the above are found to be in
correct working order, then it is likely that
the FS-7000RM itself is malfunctioning.

It is likely that the FS-7000RF itself is
malfunctioning.

• Confirm that the number of units that has

been set using the FS-7000RF's setting
switch agrees with the actual number of
the FS-7000RM units connected.

• Confirm that the unit has the correct

address settings.

• Confirm that there is no fault with the

wiring leading to the FS-7000RF.

If all of the above are found to be in
correct working order, then it is likely that
the FS-7000RF itself is malfunctioning or
equipment failures may have occurred.

Output is not being provided correctly
because of a short in the output wiring.

FS-7006PA's or
FS-7012PA's Fault
indicator lights.

– Continued on
next page –

Remove the output wiring and turn the
power on again. If the fault indicator light
goes out, then the problem may be with
the wiring. Check the wiring to determine
where the problem may be.
If the indicator light does not go out, or if it
goes out but then lights again within a
short period of time, consider whether the
following may be the problem:

Advertising