6.4.1. Gate/NOM settings

Step 1. To enable gate settings, check the "GATE" checkbox for each channel desired.

Step 2. Select gate parameters from the pull-down menu.

• Gate input sensitivity: –40 to –5 dB, in 5 dB units
• Gate reset time: 1 - 8 seconds

Step 3. Check the "NOM" checkbox for channels for which the NOM setting is desired.

Step 4. Set the NOM attenuation for all enabled channels.

It is possible to find setting value A using the following equation, assuming that N represents the
number of open microphones:
NOM attenuation = A x log10N

Notes
• The NOM attenuation and gate reset time are not set on an individual channel basis, but are jointly set for all

channels. Therefore, if a value is changed on the pull-down menu of any channel, the values of all enabled
channels are also changed in synchronization.
Also, the gate reset time and VOX reset time (refer to

p. 46

) are common.

• The GATE and NOM settings cannot be performed for the input channels for which the VOX function (refer

to

p. 46

) is set.

Gate input sensitivity

Gate reset time

NOM attenuation