Unit Preparations

SECTION III - Unit Preparations

Handling Instructions

The PRESTIGE Excellence is generally easier
to handle and maneuver once removed from
the shipping carton and pallet.

To remove the shipping carton and pallet:

Use care not to lift the unit from, or place
the unit on the front plastic control
panel, damage can occur. Use care not to
drop, bump or rotate the boiler upside
down, as damage to the boiler will result.

1. Remove any shipping straps and open the

side of the shipping carton.

2. Slide the unit with the foam inserts out of

the carton.

3. Discard all packing materials.

Wall Mounting Installation

Due to the excessive weight, the PRESTIGE
Excellence should be wall mounted using the
bracket kit provided with the boiler. The
PRESTIGE is not designed for floor installa-
tion. If floor installation is required an optional
floor stand is available through Triangle Tube.

The wall used for mounting the PRES-
TIGE Excellence must be vertically
plumbed and capable of supporting a
minimum 250 pounds [113 Kg]. Failure
to comply with these requirements could
result in personal injury, death or sub-
stantial property damage.

Wall Mounting Guidelines

1. The wall frame kit is designed for stud

spacing of 12 inch or 16 inch on centers.
For unconventional stud spacing, a solid /

secure mounting surface must be provided
for installation of the bracket.

2. DO NOT mount or attempt to mount the

wall bracket to hollow sheet rock or lathe
walls using anchors. Only install boiler to
studs or equivalent wood structure.

3. For applications using solid walls (rock,

concrete, brick, cinder block, etc.), install
the wall bracket using anchors (double
expansion shields) and bolts with washers
provided with the boiler.

4. The boiler is too heavy and bulky for a sin-

gle person to lift and attempt to mount; a
minimum of 2 people is required for
mounting the boiler.

Use extreme care not to drop the boiler
or cause bodily injury while lifting or
mounting the boiler onto the bracket.
Once mounted verify that the boiler is
securely attached to the bracket and
wall. Failure to comply with the above
guidelines could result in property dam-
age, personal injury or death.

Stud Walls -Installation

1. To distribute the weight of the boiler even-

ly when mounting onto a stud wall it is rec-
ommended to use the PRESTIGE Wall
Frame kit.

2. When using the wall frame to mount the

boiler reference the kit installation instruc-
tions and ensure the frame is securely fas-
tened to the wall.

3. If the structure of wall is questionable, in

supporting a minimum weight of 250
pounds [113 Kg.], it is recommended to use
the optional floor stand.