TriangleTube Prestige Excellence Part 1 User Manual

Page 63

Advertising
background image

SECTION XVI - Maintenance

Procedures

Maintenance Procedures

The PRESTIGE Excellence should be
inspected and serviced annually, prefer-
ably at the start of the heating season, by
a qualified service technician. In addi-
tion, the maintenance and care of the
unit as outlined on page 55 and further
explained on pages 56 through 61 should
be performed to assure maximum effi-
ciency and reliability of the unit. Failure
to service and maintain the PRESTIGE
Excellence and the system components
could result in equipment failure, caus-
ing possible severe personal injury,
death or substantial property damage.

The following information provides
detailed instruction for completing the
maintenance items outline in the mainte-
nance schedule on page 55. In addition
to this maintenance, the PRESTIGE
Excellence should be serviced at the
beginning of the heating season by a
qualified service technician.

Reported Problems

Any problems reported by the owner should be
checked, verified and corrected before pro-
ceeding with any maintenance procedures.

Check Surrounding Area

Verify that the area surrounding the PRES-
TIGE Excellence is free of combustible / flam-
mable materials or flammable vapors or liq-
uids. Remove immediately if found.

Verify that combustion air inlet area is free of
any contaminates. Refer to the list of potential
materials listed on page 5 of this manual. If
any of these products are in the area from
which the unit takes its combustion air, they
must be removed immediately or the combus-
tion air intake must be relocated to another
area.

Inspect Burner Area

Remove the boiler front jacket panel and ven-
turi inlet elbow.

Vacuum any dirt or debris from the
burner/blower components.

Re-install venturi inlet elbow and front jacket
panel when completed.

Do not use solvents to clean any of the
burner components. The components
could be damaged, resulting in unreli-
able or unsafe operation.

Check System Piping

Inspect all piping (water and gas) on the boiler
system for leaks and verify that the piping is
leak free and properly supported.

Inspect the fittings and components on the unit
and verify they are leak free.

Eliminate all boiler water system leaks.
Continual fresh make-up water will
reduce the heat exchanger life causing
boiler failure. Leaking water may also
cause severe property damage to the sur-
rounding area. Inspect the gas supply
piping using the procedure outlined on
Page 38.

WARNING

WARNING

WARNING

NOTICE

Maintenance Schedule

56

Advertising