If the old diaphragm is difficult to separate

from the diaphragm support disc, immerse

assembly in naphtha or petroleum ether. Do

not inhale vapors!

+

Check for washers between the diaphragm

support disc and the connecting rod. Make

sure that the original number is reassembled.

Position new diaphragm between diaphragm

clamping disc with square head screw and

diaphragm support disc.

+

Note: Position diaphragm with pale side

towards diaphragm clamping disc (facing

pump chamber).

+

Make sure that the square head screw of the

diaphragm clamping disc is correctly seated

in the guide hole of the diaphragm support

disc.

Lift the diaphragm at the side. Place the di-

aphragm carefully together with diaphragm

clamping disc and diaphragm support disc in

the diaphragm key.

+

Avoid damage of the diaphragm: Do not ex-

cessively bend or crease the diaphragm.

Assemble the original number of washers

between diaphragm support disc and con-

necting rod.

+

Too few washers: The pump will not attain

vacuum specification. Too many washers:

Diaphragm clamping disc will hit head cover,

causing noisy operation and possibly caus-

ing the pump to seize up.