VACUUBRAND PC 8 m. RC 6 User Manual

Page 20

Advertising
background image

page 20 of 49

and measuring instruments can only be returned when

certain procedures (see section „Notes on return to the

factory“, pg. 42) are followed.

Take advantage of our service seminars, which put special

focus on the maintenance and repair of vacuum pumps.

For details and for the online ”Instructions for repair” man-

ual see www.vacuubrand.com.

In case of normal wear, the lifetime of the diaphragms

and valves is > 10000 operating hours. Bearings have a

typical durability of 40000 h. Motor capacitors have a typi-

cal durability in the range of 10000 to 40000 h depending

strongly on operation conditions including ambient tem-

perature, humidity or load.

Ensure that the pump cannot be operated acciden-

tally. Never operate the pump if covers or other

parts of the pump are disassembled.

Switch off the pump. Disconnect the electrical pow-

er cord and wait two minutes before starting mainte-

nance to allow the capacitors to discharge.

Note: The pump may be contaminated with process

chemicals, which have been pumped during operation.

Ensure that the pump is completely decontaminated

before maintenance commences.

+

Take adequate precautions to protect people from the

effects of dangerous substances if contamination has

occurred. Use appropriate protective clothing, safety

goggles and protective gloves.

+

Wear parts have to be replaced regularly.

+

Never operate a defective or damaged pump.

+

Check every motor capacitor regularly by measuring

its capacity and estimating its time in operation. Re-

place old capacitors early enough to prevent a failure in

operation. If an old motor capacitor fails, the capacitor