outlet

ME 4R NT:

+

When

operating the pump as a compres-

sor, check that the system which you are

going to pressurize is mechanically stable.

Check that the maximum generated over-

pressure is compatible with the mechanical

stability of the pressure vessel. Do not gen-

erate overpressure in vessels other than in

those designed for that purpose.

Risk of

bursting!

Install an additional overpressure safety re-

lief device in the pressure system, if neces-

sary.

+

Especially when using the pump as vacu-

um pump provide a free and pressureless

exhaust outlet to avoid damage to pump

valves and risk of bursting.

• Reduce the transmission of vibration. Prevent mechan-

ical load due to rigid pipelines. Insert elastic hoses or

flexible elements as couplings between the pump and

rigid pipes.

Secure hose connections at the pump ap-

propriately, e.g., with hose clamps, to protect

against accidental detachment.

To reduce pump noise emanating from the pump

exhaust port (ME 4R NT / MD 4S NT), connect

an exhaust hose or use a silencer (see “Acces-

sories”, pg. 51).

NOTICE

EX

Always install outlet tubing descending from

the pump or provide other measures to avoid

backflow of condensate towards the pump.