Shutdown & storage, Notice, Me 4r nt – VACUUBRAND MZ 2S NT User Manual

Page 49

Advertising
background image

page 49 of 91

ME 4R NT:

Use the vacuum adjustment device at the inlet

port of the pump to

control the vacuum in the

system. Turning the dispensing screw controls

the amount of gases pumped from the vacuum

system:

- Turning the dispensing screw counterclock-

wise: vacuum is decreased (higher pres-

sure) (Intake of additional bleed air via the

dispensing screw.)

- Turning the dispensing screw clockwise:

vacuum is increased (lower pressure)

Use the pressure adjustment device at the out-

let port of the pump to control the

overpres-

sure accordingly:

- Turning the dispensing screw counterclock-

wise: pressure is decreased (Pump blows

off via dispensing screw.)

- Turning the dispensing screw clockwise:

pressure is increased

+

Note: Maximum permissible overpressure at the

outlet side of the ME 4R NT pump: 44 psi (3 bar)!

Shutdown & storage

The pump can be switched off under vacuum.

Condensate?

O

➨ I

(5-10min)

atm

Short-term:

- Has the pump been exposed to conden-

sate?

Allow the pump to continue to run at atmo-

spheric pressure for a few minutes.

- Has the pump been exposed to media which

may damage the pump materials or form

deposits?

Check and clean pump heads if necessary.

NOTICE

max.

overpressure:

44 psi

(3 bar)

Advertising