Setting ABO Time

The ABO (Auto Backlight OFF) function is used to automatically turn off the backlight if neither

key entry nor touch-panel entry is permitted for a certain period of time. This function is used to

set the ABO time. Enable ABO by selecting a number between 1 and 15, which corresponds to

a period of between 20 seconds and 5 minutes.

SYNTAX

int SYS_SetAboTime(int nValue);

INPUT

nValue = ABO time

0 Not activate ABO

1 to 15 Activates ABO in specified number x 20 seconds.

OUTPUT

= 0 Normal

= -1 Parameter error

= -3 VxD not registered

Note:

This function will be implemented by a software timer. Therefore, the period until the backlight is

actually turned off has an error of +/- 10 % associated with it.