Touch panel calibration, 9 touch panel calibration – Casio IT-2000W User Manual

Page 59

Advertising
background image

59

3.9 Touch Panel Calibration

Function

Adjusts the calibration of touch panel. If an inconsistency is noted between the target position and

the position actually touched on the touch panel, correct it by performing this calibration adjustment.

Fig. 3.8

Operation

Adjustment of the calibration :

 First make sure that the arrow points to in the upper left corner of the screen, then touch

the center of this

with the stylus provided.

 When the buzzer sounds, release the stylus from the touch panel.
 After the in the upper left corner disappears and the arrow moves to the in the upper

right corner, touch it in the same way.

 Do the same for the s in the lower left and lower right corners.
 When all four s are touched by the stylus, the touch panel calibration is completed.

If any improper operation has been done, press the “1” key to perform the touch panel

calibration again.

 If the “2” key is pressed after the four positions have been touched, the calibration

adjustment result takes effect and the menu screen is restored.

If the “ 2 “ key is pressed before finishing on the fourth position, the adjustment process

performed so far will be canceled.

Advertising